SECURITY LEVEL
INDIVIDUAL ZONE SENS
LEVEL [03]
ZONE=[01]=020
NOTE: The sensitivity setting on security level NC is fixed according to NILECJ – Level 2
and cannot be altered.
The above procedure can be repeated for each security level, by repeating points 2 – 5 as above
for any security level requiring to be designated.
When sensitivity adjustments are complete, other programming options may be accessed by
pressing the UP&DOWN buttons to select the required sub-MENU or press RUN(X) to return to
the normal operating mode.
4.1.2 SECURITY LEVEL AND SENSITIVITY LEVEL, ZONE ADJUSTMENTS
(
*for
ThruScan
sX/ sX-WP /s15-i/sX-i
)
The detection areas for ThruScan are divided into 3 sections; such as bottom zone(ZONE 1),
middle zone (ZONE 2) and top zone (ZONE 3). Exclusively the sensitivity level of ThruScan can be
adjusted separately in each zone. i.e. / the middle zone of ThruScan may be adjusted to be more
or less sensitive in comparison to top or bottom zones.
By this feature, the sensitivity level of zone 2 in which there would more likely be keys, cellular
phones, belts etc. can be decreased while the other zones’ can be increased.
This procedure may be altered as follows;
1- Set the Security Level Adjustments as explained in 4.1.1. After this
procedure, press the SEL(√) button, and the display on the right
side will appear.
2- Select the desired zone using Up&Down buttons and then press the SEL(√) button .
3- Adjust the desired sensitivity level on the new display. Then press the SEL(√) button .
4- Repeat the procedures in steps 2 and 3 for other zones. After the Sensitivity assignment
procedures, press RUN(X) button to exit from the MENU and to start.
NOTE: The general sensitivity level adjustments are
dominant (pls. see section 4.1.1). Therefore any separate
sensitivity level adjustment of the zones will not be valid
after such preliminary setting.
4.1.3 AUTO DESIGNATION AND AUTOMATIC SENSITIVITY ASSIGN
(
* only for
ThruScan
sX/ sX-WP /s15-i/sX-i)
This feature is very rare worldwide and its MENU helps the user to decide and to assign the
required sensitivity level very rapidly.
The assigned sensitivity level in this MENU is approximate. For more precise security requirements;
It is recommended to the user to decide on the necessary sensitivity level by using the displayed
(AD) sensitivity level only as a reference. And proceed the further adjustment manually.
This procedure is strongly suggested for more successful results!
Auto Designation and Automatic Sensitivity Assignments are set as
follows:
SECURITY LEVEL
INDIVIDUAL ZONE SENS
LEVEL [03]
ZONE [01]
AUTO DESIGNATE
MODE